Dosimetric study of three-dimensional conformal radiotherapy, electronic compensator technique, intensity-modulated radiation therapy and volumetric-modulated arc therapy in whole breast irradiation

Author:

Nantavithya Chonnipa,Saksornchai Kitwadee,Oonsiri Puntiwa,Shotelersuk Kanjana

Abstract

AbstractBackgroundWhole breast irradiation is an essential treatment after breast-conserving surgery (BCS). However, there are some adverse effects from inhomogeneity and dose to adjacent normal tissues.ObjectiveAim of this study was to compare dosimetry among standard technique, three-dimensional conformal radiotherapy (3D-CRT), and advanced techniques, electronic compensator (ECOMP), inverse intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT).MethodsWhole breast irradiation treatment plans of patients who had underwent BCS and whole breast irradiation were re-planned with all four techniques. Clinical target volume was contoured according to the Radiation Therapy Oncology Group atlas for breast only in patients who had negative node or ductal carcinoma in situ and breast with chest wall for patients with positive node. Planning target volume was non-uniformly expanded. Dose prescription was 50 Gy in 25 fractions with 6 MV photon energy.ResultsIn total, 25 patients underwent whole breast irradiation with computed tomography simulation from November 2013 to November 2014 were included. Six patients with positive nodes were re-planned for breast with chest wall irradiation and 19 patients with negative nodes were re-planned for breast only irradiation. Primary outcome, radical dose homogeneity index (HI) of 3D-CRT, ECOMP, IMRT and VMAT were 0·865, 0·889, 0·890 and 0·866, respectively. ECOMP and IMRT showed significant higher HI than 3D-CRT (p-value<0·001). Secondary outcome, conformity index (CI) of advanced technique were significantly better than 3D-CRT. Lung V20, mean ipsilateral lung dose (MILD), mean heart dose (MHD), heart V25, heart V30 of advanced techniques were also lower than 3D-CRT. ECOMP had better mean lung dose (MLD), mean contralateral lung dose (MCLD) and mean contralateral breast dose (MCBD) when compared with 3D-CRT. Monitor units of advanced techniques were significantly higher than 3D-CRT.ConclusionsHI of ECOMP and IMRT were significantly higher than 3D-CRT technique. All advanced techniques showed statistically better in CI. Lung V20, MILD, heart V25 and heart V30 of advanced techniques were lower than 3D-CRT. However, only ECOMP showed decreased MLD, MHD, MCLD and MCBD when compared with 3D-CRT.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3