Patterns of recurrence in patients receiving conformal radiation for intracranial meningioma: a single-institution experience

Author:

Rajkrishna B.ORCID,Rajesh Balakrishnan,Patricia Sebastian,Selvamani B.

Abstract

AbstractAim:To evaluate the patterns of recurrence following postoperative conformal radiotherapy (RT) for intracranial meningioma.Materials and methods:Eighty-six patients who received conformal RT for intracranial meningiomas from 2014 to 2017 were retrospectively analysed. For documented recurrences, recurrence imaging was deformably co-registered to planning CT scan. In-field recurrence was defined as recurrence within the 90% isodose line, and out-of-field recurrences were those that occurred outside the 90% isodose line. We present the demographic details, surgical and RT details, outcomes and patterns of recurrence.Results:The median age was 46 years (range 17–72); 82·6% underwent surgery [46·5% had subtotal resection (STR), 43·7% gross tumour resection (GTR), 5·6% biopsy] and 17·4% had no surgery. Among these, 53·5% were WHO grade 2; 27·9% grade 1; and 1·2% grade 3 meningioma. Fifty per cent received stereotactic RT (SRT), 46·5% 3D conformal RT (3DCRT) and 3·5% intensity-modulated RT (IMRT). The mean clinical target volume (CTV) and planning target volume (PTV) margins were 4·5 mm (range 0–15) and 3·9 mm (range 1–5), respectively. The doses ranged from 54 to 59·4 Gy. The median follow-up after RT was 1·7 years (range 0·2–4·7). 17·4% were lost to follow-up, 5·4% had recurrence, and the median time to recurrence after completion of RT was 2 years (range 0·7–2·9). The 3-year recurrence-free rate was 81·5%. Three patients had in-field and two had in-field and out-of-field recurrence. Among the cases with recurrence, three received SRT, one 3DCRT and one IMRT. Four were grade 2 and one was grade 3 tumour, and the CTV margin ranged from 0 to 5 mm, and the PTV margin ranged from 3 to 5 mm.Conclusion:Local recurrence was seen in grade 2 and 3 meningiomas. SRT probably had more recurrence as they had lesser CTV margin. Increased CTV margin, escalated dose up to 59·4 Gy and 3DCRT/IMRT may be helpful in preventing local recurrences in grade 2 and grade 3 meningiomas.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3