Is 5 mm breath-hold window (BHW) sufficient to treat carcinoma left breast patients post-conservative surgery: a comparative study using forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT)

Author:

Kalyanasundaram KarthikeyanORCID,Vellaiyan Subramani

Abstract

Abstract Purpose: The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery. Methods: Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated. Results: Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans. Finding: The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3