Dosimetric variations for high-risk prostate cancer by VMAT plans due to patient’s weight changes

Author:

Miguel DavidORCID,de la Llana Victor,Martinez Daniel,del Castillo Angel,Alonso Delfín,de Frutos Jesús-María,Andrés Carlos,Agulla Manuel,Torres Ricardo,López-Lara Francisco

Abstract

AbstractPurpose:The aim of this study is to investigate the impact of anatomical changes in prostate cancer patients on the target coverage when using 6 MV beams-VMAT therapy and to propose strategies that allow us to evaluate the dose or correct it by normalization without having to perform a new simulation.Methods and materials:Ten patients of high-risk prostate cancer were chosen for the study. All test plans were delivered using the same isocenter and monitor units as the original plan and compared against the original unedited plan. The expansion and contraction of body contours due to size changes was mimicked by increasing and decreasing the body contour with depths of −2, −1·5, …, 1·5, 2 cm, in the anterior, and both lateral directions of the patient. A total of 90 plans were evaluated, 9 for each patient. Dose-volume histogram statistics were extracted from each plan and normalized to prescription dose.Results:Weight changes resulted in considerable dose modifications to the target and critical structures. Plans were found to be varied with 2·9% ± 0·3% per cm SSD change for VMAT treatment with a correlation index close to one. Therefore, doses variations were linear to the changes of depth. Gamma index evaluation was performed for the 10 renormalized plans. All of them passed criteria of 3%/3 mm in at least 98.2% of points. Eight of them passed criteria in 99% points. Gamma index 4%/4 mm passed 100% points in all patients for the chosen region of interest.Conclusions:The dosimetry estimation presented in this study shows important data for the radiation oncology staff to justify whether a CT rescan is necessary or not when a patient experiences weight changes during treatment. Based on the results of our study, discrepancies between real dose and planned dose were >5% for 1·7 cm of difference in external contour in the anterior and both lateral directions of the patient.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3