Dosimetric comparison of sequential intensity-modulated radiation therapy (IMRT) and simultaneous integrated boost IMRT for lymph node-positive cervical cancer

Author:

Mohanty SamarpitaORCID,Hajare RaghavendraORCID,Gurram LavanyaORCID,Aravindakshan Dheera,Midha Vanisha,Chopra SupriyaORCID,Mahantshetty UmeshORCID

Abstract

Abstract Introduction: Nodal boost is being increasingly employed to escalate the dose to involved nodes in node-positive cervical cancer. The study aimed to compare the dosimetric differences between sequential boost intensity-modulated radiation therapy (SeB-IMRT) and simultaneous integrated boost IMRT (SIB-IMRT) in terms of target coverage and organs-at-risk (OARs) with special emphasis on the effect of nodal shrinkage and anatomical change of normal tissues during radiotherapy. Methods: Two computed tomography (CT) datasets (of phase I and phase II) of 40 patients of node-positive cervical cancer treated with SeB-IMRT [planning target volume (PTV) 45/25] followed by SeB to residual nodes (PTV 12·6/7) were utilised. SIB-IMRT1 plan consisted of PTV pelvis and para-aortic nodal region (PTV 45/25) and SIB to gross nodes (PTV 55/25). In order to account for the change in nodal and normal tissue topography during treatment, a third plan (SIB-IMRT2) was generated by utilising the SIB-IMRT1 plan for 44 Gy in 20 fractions and reproducing the plan on the second CT dataset for 11 Gy in 5 fractions. Dosimetric parameters of the three plans were compared using the Friedman test with Bonferroni correction. Results: We observed that the doses to OARs (bowel, rectum and bladder) were significantly higher in SeB-IMRT plan as compared to the SIB-IMRT plans. V40 Gy of bowel for SeB-IMRT, SIB-IMRT1 and SIB-IMRT2 plans were 354·8 cc, 271 cc and 321·8 cc, respectively (p = 0·001), whereas V30 Gy were 687·8 cc, 635·5 cc and 680 cc, respectively (p = 0·001). The target coverage was marginally better in SeB-IMRT plan as compared to SIB-IMRT1 and SIB-IMRT2 plans (V95% = 99·2 versus 97·7 versus 97·9, respectively, p = 0·000) Conclusion: SIB-IMRT led to better sparing of OARs, especially bowel. However, the magnitude of benefit decreases if the change in nodal and normal tissue topography during radiotherapy is not considered implying the need for frequent image guidance when SIB-IMRT is planned for node-positive cervical cancer.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3