AbstractAim:The purpose of this study is to investigate the feasibility of proton arc therapy (PAT) using the double-scattering MEVION-S250 proton system. The treatment planning and dose delivery parameters from PAT were compared with conventional treatment planning techniques.Materials and methods:PAT was simulated with multiple conformal and fixed-aperture beams (5–15) using the MEVION-S250-double-scattering proton system. Conformal apertures were simulated with the Eclipse-treatment-planning system: (a) using a static single aperture that provides the best average conformal circular or rectangular apertures to cover the tumour from different angular views (SPAT), and (b) dynamic conformal apertures of the tumour shape at each irradiation angle that can be obtained from a multi-leaf-collimator system (DPAT).Results:The DPAT and SPAT plans provided superior dose coverage and sparing of normal tissues in comparison with conventional plans (CPT). The entrance normal tissue and skin doses (<40%) were lowered significantly by delivering dose from different directions over a wider angular view compared to conventional plans that have large entrance dose from only two fields. While the mean and minimum doses from PAT and CPT were comparable, the maximum doses from arc plans were lower than the maximum doses in conventional plans. The SPAT and DPAT plans had comparable dose parameters for regularly shaped targets. The heterogeneity index (HI) was superior in PAT plans which improved with increasing number of beams in arc plans for the different treatment sites. The conformality index (CI) depends on the treatment site and complexity of the shape of the planning target volume where for brain, pancreatic and lung tumours, PAT plans conformality was comparable and sometimes superior to CPT; and HI and CI were generally better in DPAT compared to SPAT.Conclusions:PAT plans have superior dose coverage and sparing of normal tissues compared to CPT plans using the MEVION double-scattering system as shown in this simulation study. Ideally, conformal proton arcs require beam shaping and dose delivery with the gantry moving; however, the MEVION double-scattering system lacks a multi-leaf collimator system and cannot deliver dose during gantry rotation. The single aperture conformal proton therapy technique is more time and cost effective compared with conventional techniques that are used currently with the MEVION proton therapy system because of the elimination of the need for patient-specific compensators. In present study, PAT was simulated with the MEVION double-scattering proton therapy system; however, it can be performed also with other proton therapy systems.
Publisher
Cambridge University Press (CUP)
Subject
Oncology,Radiology Nuclear Medicine and imaging
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献