Simulation study of proton arc therapy with the compact single-room MEVION-S250 proton therapy system

Author:

Ferguson Sven,Ahmad Salahuddin,Ali ImadORCID

Abstract

AbstractAim:The purpose of this study is to investigate the feasibility of proton arc therapy (PAT) using the double-scattering MEVION-S250 proton system. The treatment planning and dose delivery parameters from PAT were compared with conventional treatment planning techniques.Materials and methods:PAT was simulated with multiple conformal and fixed-aperture beams (5–15) using the MEVION-S250-double-scattering proton system. Conformal apertures were simulated with the Eclipse-treatment-planning system: (a) using a static single aperture that provides the best average conformal circular or rectangular apertures to cover the tumour from different angular views (SPAT), and (b) dynamic conformal apertures of the tumour shape at each irradiation angle that can be obtained from a multi-leaf-collimator system (DPAT).Results:The DPAT and SPAT plans provided superior dose coverage and sparing of normal tissues in comparison with conventional plans (CPT). The entrance normal tissue and skin doses (<40%) were lowered significantly by delivering dose from different directions over a wider angular view compared to conventional plans that have large entrance dose from only two fields. While the mean and minimum doses from PAT and CPT were comparable, the maximum doses from arc plans were lower than the maximum doses in conventional plans. The SPAT and DPAT plans had comparable dose parameters for regularly shaped targets. The heterogeneity index (HI) was superior in PAT plans which improved with increasing number of beams in arc plans for the different treatment sites. The conformality index (CI) depends on the treatment site and complexity of the shape of the planning target volume where for brain, pancreatic and lung tumours, PAT plans conformality was comparable and sometimes superior to CPT; and HI and CI were generally better in DPAT compared to SPAT.Conclusions:PAT plans have superior dose coverage and sparing of normal tissues compared to CPT plans using the MEVION double-scattering system as shown in this simulation study. Ideally, conformal proton arcs require beam shaping and dose delivery with the gantry moving; however, the MEVION double-scattering system lacks a multi-leaf collimator system and cannot deliver dose during gantry rotation. The single aperture conformal proton therapy technique is more time and cost effective compared with conventional techniques that are used currently with the MEVION proton therapy system because of the elimination of the need for patient-specific compensators. In present study, PAT was simulated with the MEVION double-scattering proton therapy system; however, it can be performed also with other proton therapy systems.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3