Analysis of the interplay effect in lung stereotactic ablative radiation therapy based on both breathing motion and plan characteristics

Author:

Ali Asmaa M.,Greenwood Jason B.ORCID,Varasteh Mohammad,Esteve Sergio,Jeevanandam Prakash,Göpfert Fabian,Irvine Denise M.,Hounsell Alan R.,McGarry Conor K.

Abstract

Abstract Introduction: Stereotactic ablative radiotherapy (SABR) is susceptible to challenges for tumours affected by intrafraction organ motion. This study aims to investigate the effect of breathing characteristics and plan complexity on the interplay effect. Methods: A patient-specific interplay effect evaluation was performed using in-house software with an alpha version of the treatment planning verification software Verisoft (PTW-Freiburg, Germany) on VMAT plans. The OCTAVIUS 4D phantom was used to acquire the static dose distribution, and the simulation approach was utilised to generate the moving dose distribution. The influence of plan complexity, PTV size, number of breaths, and motion amplitudes on the interplay effect were examined. The dose distribution of two extreme phases—end-inhale and end-exhale—was considered using the gamma criteria of 2%/2 mm for the interplay effect evaluation. Results: A strong correlation was found between the motion amplitude (p < 0.001) and the NBs (p < 0.001) with the gamma-passing rate. No correlation was found between the gamma-passing rate and the PTV size or plan complexity. Conclusion: The simulation tool allowed the analysis of a large number of breathing traces, demonstrating how free-breathing patients, suspected of high interplay, could be selected for other motion management solutions. The simulated cases showed strong interplay effects for long breathing periods with extended motion amplitudes in a small group of patients.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology, Nuclear Medicine and imaging

Reference40 articles.

1. Breathing-motion induced interplay effects for stereotactic body radiotherapy of liver tumours using flattening-filter free volumetric modulated arc therapy

2. Effect of plan complexity on the dosimetry, delivery accuracy, and interplay effect in lung VMAT SBRT with 6 MV FFF beam;Ge;Strahlenther Onkol,2022

3. 33. PTW. OCTAVIUS 4D Modular Solutions for 4D Patient and Machine QA. In 2018.

4. Dosimetric impact of interplay effect in lung IMRT and VMAT treatment using in-house dynamic thorax phantom;Pawiro;J Phys Conf Series,2016

5. Single-fraction stereotactic ablative body radiation therapy for primary and metastasic lung tumor: A new paradigm?

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3