Real-world effectiveness of infection prevention interventions for reducing procedure-related cardiac device infections: Insights from the veterans affairs clinical assessment reporting and tracking program

Author:

Asundi Archana,Stanislawski Maggie,Mehta Payal,Baron Anna E.,Mull Hillary J.,Ho P. Michael,Zimetbaum Peter J.,Gupta Kalpana,Branch-Elliman Westyn

Abstract

AbstractObjective:To measure the association between receipt of specific infection prevention interventions and procedure-related cardiac implantable electronic device (CIED) infections.Design:Retrospective cohort with manually reviewed infection status.Setting:Setting: National, multicenter Veterans Health Administration (VA) cohort.Participants:Sampling of procedures entered into the VA Clinical Assessment Reporting and Tracking-Electrophysiology (CART-EP) database from fiscal years 2008 through 2015.Methods:A sample of procedures entered into the CART-EP database underwent manual review for occurrence of CIED infection and other clinical/procedural variables. The primary outcome was 6-month incidence of CIED infection. Measures of association were calculated using multivariable generalized estimating equations logistic regression.Results:We identified 101 procedure-related CIED infections among 2,098 procedures (4.8% of reviewed sample). Factors associated with increased odds of infections included (1) wound complications (adjusted odds ratio [aOR], 8.74; 95% confidence interval [CI], 3.16–24.20), (2) revisions including generator changes (aOR, 2.4; 95% CI, 1.59–3.63), (3) an elevated international normalized ratio (INR) >1.5 (aOR, 1.56; 95% CI, 1.12–2.18), and (4) methicillin-resistant Staphylococcus colonization (aOR, 9.56; 95% CI, 1.55–27.77). Clinically effective prevention interventions included preprocedural skin cleaning with chlorhexidine versus other topical agents (aOR, 0.41; 95% CI, 0.22–0.76) and receipt of β-lactam antimicrobial prophylaxis versus vancomycin (aOR, 0.60; 95% CI, 0.37–0.96). The use of mesh pockets and continuation of antimicrobial prophylaxis after skin closure were not associated with reduced infection risk.Conclusions:These findings regarding the real-world clinical effectiveness of different prevention strategies can be applied to the development of evidence-based protocols and infection prevention guidelines specific to the electrophysiology laboratory.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3