Author:
Walker David S.,O'Dell J. David,Wolt Jeff D.,Rhodes G. Neil,Graveel John G.
Abstract
A tractor mounted sampler was constructed which allows large soil columns to be obtained rapidly and with minimal physical effort. The machine utilizes the hydraulic system of a tractor to push a steel sampling cylinder containing 30.5-cm id. polyvinyl chloride (PVC) pipe into the soil, after which the hydraulic cylinder is retracted to pull the pipe and enclosed soil from the ground. Columns 68 cm in length were taken with a hydraulic cylinder pressure of approximately 10 MPa. Soil separated evenly at the bottom of the columns, and compaction was measured to be approximately 5%. This is a relatively simple and rapid method for obtaining large soil columns for use in pesticide leaching studies.
Publisher
Cambridge University Press (CUP)
Subject
Plant Science,Agronomy and Crop Science
Reference17 articles.
1. Mobility and distribution of buthidazole and metabolites in four leached soils;Weber;Weed Sci.,1982
2. Water Movement in Undisturbed Swelling Clay Soil
3. Clay S. A. , and Koskinen W. C. 1989. A soil column technique to determine the influence of tillage management on herbicide movement. Abstr. Weed Sci. Soc. Am., p. 97.
4. Flow Patterns During Extended Saturated Flow in Two, Undisturbed Swelling Clay Soils with Different Macrostructures
5. Abbreviations: PVC, polyvinyl chloride.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献