AbstractData-constrained modeling is a method that enables three-dimensional distribution of mineral phases and porosity in a sample to be modeled based on micro-computed tomography scans acquired at different X-ray energies. Here we describe an alternative method for measuring porosity, synchrotron K-edge subtraction using xenon gas as a contrast agent. Results from both methods applied to the same Darai limestone sample are compared. Reasonable agreement between the two methods and with other porosity measurements is obtained. The possibility of a combination of data-constrained modeling and K-edge subtraction methods for more accurate sample characterization is discussed.
Publisher
Cambridge University Press (CUP)
Reference32 articles.
1. Yang Y.S. , Tulloh A. , Chen F. , Liu K.Y. , Clennell B. & Taylor J. (2013 b). Data-constrained characterization of sandstone microstructures with multi-energy X-ray CT. 11th International Conference on X-Ray Microscopy (XRM2012). J Phys: Conf Ser. 463, 012048.
2. A data-constrained modelling approach to sandstone microstructure characterisation
3. Feasibility of a data-constrained prediction of hydrocarbon reservoir sandstone microstructures
4. Yang S. , Mayo S. , Pervukhina M. , Clennell B. , Esteban L. , Irvine S. , Siu K. , Maksimenko A. & Tulloh A. (2014 a). Carbonate rock X-ray CT and DCM microstructure data. v1. CSIRO. Data Collection. 10.4225/08/5476787E08766.