Abstract
One of the main capabilities of atom probe tomography (APT) is the ability to not only identify but also characterize early stages of precipitation at length scales that are not achievable by other techniques. One of the most popular methods to identify nanoscale clustering in APT data, based on the density-based spatial clustering of applications with noise (DBSCAN), is used extensively in many branches of research. However, it is common that not all of the steps leading to the selection of certain parameters used in the analysis are reported. Without knowing the rationale behind parameter selection, it may be difficult to compare cluster parameters obtained by different researchers. In this work, a simple open-source tool, PosgenPy, is used to justify cluster search parameter selection via providing a systematic sweep through parameter values with multiple randomizations to minimize a false-positive cluster ratio. The tool is applied to several different microstructures: a simulated material system and two experimental datasets from a low-alloy steel . The analyses show how values for the various parameters can be selected to ensure that the calculated cluster number density and cluster composition are accurate.
Funder
Engineering and Physical Sciences Research Council
Rolls-Royce
Publisher
Cambridge University Press (CUP)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献