Effectiveness, efficacy, and safety of wearable cardioverter-defibrillators in the treatment of sudden cardiac arrest – Results from a health technology assessment

Author:

Aidelsburger PamelaORCID,Seyed-Ghaemi Janine,Guinin Christian,Fach Andreas

Abstract

ObjectivesTo assess the effectiveness, efficacy, and safety of a wearable cardioverter-defibrillator (WCD) in adult persons with high risk for sudden cardiac arrest and for which an implantable cardioverter is currently not applicable.MethodsWe performed a systematic literature search in Medline, Embase, Cochrane Library, and CRD-databases. Study selection was performed by two reviewers independently. Data were presented quantitatively; due to heterogeneity of studies no meta-analysis was performed.ResultsOne randomized-controlled trial (RCT), one non-randomized comparative trial, and forty-four non-comparative trials were included. The RCT reported an overall mortality of 3.1 percent in the WCD group versus 4.9 percent in controls (relative risk [RR]: .64; 95 percent confidence interval [CI], .43–.98, p = .04), but no significant effect on arrhythmia-related mortality. The RR for arrhythmia-related mortality amounted to .67 (95 percent CI, .37–1.21, p = .18) as assessed in the RCT. Appropriate shocks were observed in 1.3 percent of patients in both comparative studies, and inappropriate shocks in .6 percent of patients in the RCT. Termination of ventricular tachycardia (VT) or ventricular fibrillation (VF) was successful in 75 to 100 percent of appropriate shocks in all studies. Adverse events assessed in the RCT showed a lower incidence of shortness of breath (38.8 percent vs. 45.3 percent; p = .004), higher incidence of rash at any location (15.3 percent vs. 7.1 percent; p < .001), and higher incidence of itching at any location (17.2 percent vs. 6.4 percent; p < .001) for WCD.ConclusionsAvailable evidence demonstrates that the WCD detects and terminates VT/VF events reliably and shows a high rate of appropriate shocks in mixed patient populations. Data of large registries confirm that the WCD is a safe intervention.

Publisher

Cambridge University Press (CUP)

Subject

Health Policy

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3