Abstract
Abstract
Hand hygiene (HH) performance on entering intensive care units (ICUs) is commonly accepted but often inadequately performed. We developed a simple, inexpensive module that connects touchless dispensers of alcohol sanitiser (TDAS) to the automatic doors of a paediatric ICU, and assessed the impact of this intervention on HH compliance of hospital staff and visitors. A prospective observational study was conducted over a 3-week period prior to the intervention, followed by a 4-week period post intervention. HH performance was monitored by a research assistant whose office location enabled direct and video-assisted observation of the ICU entrance. A total of 609 entries to the ICU was recorded. Overall HH performance was 46.9% (92/196) before and 98.5% (406/413) after the intervention. Our findings suggest that HH performance on entering an ICU can be improved via a mechanism that makes operation of an automatic door dependent on use of a TDAS system, and thus contribute to infection control.
Publisher
Cambridge University Press (CUP)
Subject
Infectious Diseases,Epidemiology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献