Avoid the Goose! Paramedic Identification of Esophageal Intubation by Ultrasound

Author:

Lema Penelope C.ORCID,O’Brien Michael,Wilson Juliana,James Erika St.,Lindstrom Heather,DeAngelis John,Caldwell Jennifer,May Paul,Clemency Brian

Abstract

AbstractObjectivesRapid identification of esophageal intubations is critical to avoid patient morbidity and mortality. Continuous waveform capnography remains the gold standard for endotracheal tube (ETT) confirmation, but it has limitations. Point-of-care ultrasound (POCUS) may be a useful alternative for confirming ETT placement. The objective of this study was to determine the accuracy of paramedic-performed POCUS identification of esophageal intubations with and without ETT manipulation.MethodsA prospective, observational study using a cadaver model was conducted. Local paramedics were recruited as subjects and each completed a survey of their demographics, employment history, intubation experience, and prior POCUS training. Subjects participated in a didactic session in which they learned POCUS identification of ETT location. During each study session, investigators randomly placed an ETT in either the trachea or esophagus of four cadavers, confirmed with direct laryngoscopy. Subjects then attempted to determine position using POCUS both without and with manipulation of the ETT. Manipulation of the tube was performed by twisting the tube. Descriptive statistics and logistic regression were used to assess the results and the effects of previous paramedic experience.ResultsDuring 12 study sessions, from March 2014 through December 2015, 57 subjects participated, evaluating a total of 228 intubations: 113 tracheal and 115 esophageal. Subjects were 84.0% male, mean age of 39 years (range: 22 - 62 years), with median experience of seven years (range: 0.6 - 39 years). Paramedics correctly identified ETT location in 158 (69.3%) cases without and 194 (85.1%) with ETT manipulation. The sensitivity and specificity of identifying esophageal location without ETT manipulation increased from 52.2% (95% confidence interval [CI], 43.0-61.0) and 86.7% (95% CI, 81.0-93.0) to 87.0% (95% CI, 81.0-93.0) and 83.2% (95% CI, 0.76-0.90) after manipulation (P<.0001), without affecting specificity (P=.45). Subjects correctly identified 41 previously incorrectly identified esophageal intubations. Paramedic experience, previous intubations, and POCUS experience did not correlate with ability to identify tube location.Conclusion:Paramedics can accurately identify esophageal intubations with POCUS, and manipulation improves identification. Further studies of paramedic use of dynamic POCUS to identify inadvertent esophageal intubations are needed.LemaPC, O’BrienM, WilsonJ, St. JamesE, LindstromH, DeAngelisJ, CaldwellJ, MayP, ClemencyB.Avoid the goose! Paramedic identification of esophageal intubation by ultrasound. Prehosp Disaster Med.2018;33(4):406410

Publisher

Cambridge University Press (CUP)

Subject

Emergency,Emergency Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3