Comparison of Delivered Volumes and Airway Pressures when Ventilating Through an Endotracheal Tube with Bag-Valve Versus Demand-Valve

Author:

Mosesso Vincent N.,Lukitsch Karen,Menegazzi James,Mosesso Janet

Abstract

AbstractIntroduction:Use of an oxygen-powered demand-valve to ventilate through an endotracheal tube is considered inappropriate due to concern regarding excessive airway pressure.Hypothesis:It was hypothesized that ventilation through an endotracheal tube using a bag-valve (BV) device and the recently modified demand-valve (DV) would produce similar tidal volumes (Vt), minute ventilation (MV), and peak airway pressures (PAP).Methods:This is a prospective, randomized vitro experimental model. Subjects were blinded to volume and pressure gauges. Thirty-nine EMTs (mean age 27 years with mean experience five years) volunteered to ventilate a mechanical test lung through an endotracheal tube for 10 minutes. Each subject was randomized to BV or DV and to either normal (0.1 L/cm H2O) or poor (0.04 L/cm H2O) lung compliance. This DV delivers set flow of 40 L/min at maximum 50±5 cm H2O. Subjects were instructed to use their “usual” technique for an average size adult in respiratory arrest with normal heart rate and blood pressure. The Vt and PAP were recorded for each breat; the MV and maximum PAP (PAP-max) for each minute was noted. Data were analyzed using repeated measures ANOVA and Tuke multiple comparisons with alpha set at 0.05.Results:Overall average tidal volumes and minute ventilations were acceptable with both ventilalory devices at both normal and poor compliance for the first, fifth, and 10th minute of continuous ventilation. Average airway pressures and peak airway pressures during the first, fifth, and 10th minute of ventilation all were significantly higher with those of the bag-valve than with the use of the demandvalve at both normal and poor compliance.Conclusion:In this model, ventilation with bag-valve and demand-valve both provided more than adequate Vt and MV; values wer similar except for higher Vt with BV at normal compliance. However, DV yielded significantly lower PAP and PAPmax at both poor and normal compliance. These findings need corrobration in an in vivo model, but suggest that with proper training, demand-valve ventilation through an endotracheal tube may be preferable.

Publisher

Cambridge University Press (CUP)

Subject

Emergency Nursing,Emergency Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3