Abstract

AbstractIntroduction:Previous studies have proven the success of the EsophagealTracheal Combitube (ETC) as a primary airway, but not as a rescue airway.Objective:The object of this study was to observe success and complication rates of paramedic placement of an ETC as a rescue airway, and to compare success rates with endotracheal tube (ETT) intubation. The primary outcome indicator was placement with successful ventilation. Complication rates, esophageal placement, and return of spontaneous circulation (ROSC) were secondary measures.Methods:A retrospective review of the records of patients who had ETC attempts by Emergency Medical Services (EMS) was conducted for a period of three years. Complications were defined a priori. The ETC is used primarily as rescue airway for a failed attempt at an endotracheal tube (ETT) intubation. A control group for ETT placements was drawn from the EMS quality assurance (QA) database for the same period.Results:Esophageal-Tracheal Combitube insertion was attempted on 162 patients, of which, 113 (70%) were successful, 46 (28%) failed, and the outcome of three (2%) was not recorded. Inability to place the ETC occurred in 29 (18%) patients, and accounted for 48% (22/46) of failures. The use of the ETC caused dental trauma in one patient, and one placement of the ETC was related to the onset of subcutaneous emphysema. Blood in the ETC from active upper gatrointestinal bleeding occurred in nine patients (6%), and four tubes (3%) became dislodged en route to the hospital. The a priori complication rate was 44/162 (27%). Inability to determine placement of the ETC due to emesis from both ports occurred in 21 cases. Combining these problems with the a priori complications, the overall rate was 40% (65/162). EsophagealTracheal Combitube location was noted in a subset of 90 charts, of which, 76 (84%) were esophageal, and 14 (16%) were tracheal. Thirteen of 126 (10%) patients in cardiac arrest had return of spontaneous circulation (ROSC) in the field after placement of the ETC. An ETT was attempted in 128 control patients, of which, 107 (84%) were successful, 21 (16%) failed (odds ratio (OR) for ETT vs. ETC = 2.1; 95% CI = 1.12–3.86).Conclusion:Despite a low ROSC rate, the complication and success rates of ETC are acceptable for a rescue airway device. Tracheal placement of the Combitube is uncommon, but requires fail-safe discrimination. Similar to previous reports, the success ratio for ETT was greater than for the ETC.

Publisher

Cambridge University Press (CUP)

Subject

Emergency,Emergency Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3