No difference found in safety or efficacy of balloon atrial septostomy performed at the bedside versus the catheterisation laboratory

Author:

Savorgnan Fabio,Zaban Nicholas B.,Elhoff Justin J.,Ross Michael M.,Breinholt John P.

Abstract

AbstractBackgroundBalloon atrial septostomy is performed in infants with dextro-transposition of the great arteries to improve oxygenation before surgery. It is performed in the catheterisation laboratory with fluoroscopy or at the bedside using echocardiography. It is unclear whether procedural safety and efficacy is superior in one location versus the other, although the bedside procedure may improve resource utilisation and present an opportunity for reducing cost. This study compares safety and efficacy of atrial septostomy performed at the patient’s bedside versus the catheterisation laboratory.MethodsNeonates with dextro-transposition of the great arteries who underwent balloon atrial septostomy from October, 2000 to January, 2014 were included. Medical and procedural records, echocardiograms, and catheterisation data were reviewed. Comparisons between the two procedural locations included patient demographics, pre- and post-procedure oxygen saturations, and outcomes. Complications reviewed included bleeding, arrhythmia, cardiac trauma, stroke, and death. Coronary artery evaluations were recorded. T-tests were used for continuous variables, and Fisher’s exact tests were used for all categorical variables. Wilcoxon rank sum and analysis of covariance modelling were used for time variables and oxygen saturation, respectively.ResultsA total of 88 infants met the inclusion criteria. Among them, 53 underwent septostomy at the bedside and 35 underwent septostomy in the catheterisation laboratory. No safety or outcome benefit was identified between the two procedural locations.ConclusionSeptostomy performed at the bedside and in the catheterisation laboratory had similar outcomes and efficacy. Further, bedside septostomy has the advantage of no radiation exposure, and obviating risks with patient transfer from the ICU to the catheterisation laboratory.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3