Influence of the introduction of Amplatzer device on the interventional closure of defects within the oval fossa in children

Author:

Rastegari Mahvash,Redington Andrew N.,Sullivan Ian D.

Abstract

Since June 1998, we have used an Amplatzer device whenever considered appropriate in patients with isolated defects within the oval fossa. The aim of this study was to define the total cohort of patients with isolated defects in the oval fossa seen at this hospital, so as to assess the impact of this policy on contemporary management. In the two-year period commencing 1st June 1998, 116 patients older than 6 months were seen with an isolated septal defect within the oval fossa. Mean age at closure or last review was 5.8 years, with a range from 0.5 to 20 years. In total, 42 (36%) patients were assigned to surgical closure, 25 (22%) to closure using an Amplatzer device, and 49 (42%) remained under clinical follow up. Direct referral for surgical closure occurred in 24 (21%) patients, in whom transcatheter closure was considered not appropriate after transthoracic echocardiography. Transoesophageal echocardiography was performed in 45 (39%) patients to assess suitability for closure using the Amplatzer device. Of these, 20 (44% of the group undergoing transoesophageal echocardiography) were considered unsuitable for closure in this fashion. Of these, 8 were referred for surgery and 2 with small defects were considered not to require closure. Patients undergoing closure with the device were older than the group referred for surgical closure, having a median age of 7.8 versus 3.6 years, and stayed for a shorter period in hospital. Those closed using the device stayed for 2 days, as opposed to a median of 5 days, with a range from 4 to 10 days for those undergoing surgical closure. Closure was complete as assessed by echocardiography after follow up of 1–3 months in both groups. There were no recognised complications related to insertion of the device, whereas transient postoperative morbidity occurred in 38% of those closed surgically. Insertion of an Amplatzer device was considered to be appropriate in 37% of patients older than 6 months requiring closure of an atrial septal defect in the oval fossa.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3