Does the technique of interventional closure of perimembranous ventricular septal defect reduce the incidence of heart block?

Author:

Bentham James R.,Gujral Arjun,Adwani Satish,Archer Nick,Wilson Neil

Abstract

AbstractObjectiveTo describe the difficulties and differing techniques in the transcatheter placement of amplatz ventricular septal defect devices to close perimembranous ventricular septal defects and place these in the context of the expanding literature on ventricular septal defect catheter closure.BackgroundSurgery remains the established first-line therapy for closure of haemodynamically significant perimembranous ventricular septal defects. Transcatheter techniques appeared to promise a possible alternative, obviating the need for cardiac surgery. However, significant technical and anatomical constraints coupled with ongoing reports of a high incidence of heart block have prevented these hopes from being realised to any significant extent. It is likely that there are important methodological reasons for the high complication rates observed. The potential advantages of transcatheter perimembranous ventricular septal defect closure over surgery warrant further exploration of differing transcatheter techniques.MethodsBetween August, 2004 and November, 2009, 21 patients had a perimembranous ventricular septal defect closed with transcatheter techniques. Of these, 14 were closed with a muscular amplatz ventricular septal defect device. The median age and weight at device placement were 8 years, ranging from 2 to 19 years, and 18.6 kilograms, ranging from 10 to 21 kilograms, respectively.ResultsThere were 25 procedures performed on 23 patients using 21 amplatz ventricular septal defect devices. Median defect size on angiography was 7.8 millimetres, ranging from 4 to 14.3 millimetres, with a median device size of 8 millimetres, ranging from 4 to 18 millimetres, and a defect/device ratio of 1.1, with a range from 0.85 to 1.33. Median procedure time was 100 minutes, with a range from 38 to 235 minutes. Adverse events included device embolisation following haemolysis in one, and new aortic incompetence in another, but there were no cases of heart block. Median follow-up was 41.7 months, with a rangefrom 2 to 71 months.ConclusionsEvaluating transcatheter closure of perimembranous ventricular septal defect using amplatz ventricular septal defect devices remains important, if a technically feasible method with low and acceptable complication rates is to be identified. Incidence of heart block may be minimised by avoiding oversized devices, using muscular devices, and accepting defeat if an appropriately selected device pulls through. Given the current transcatheter technologies, the closure of perimembranous ventricular septal defects should generally be performed in children when they weigh at least 10 kilograms.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3