Transcatheter closure of various types of defects within the oval fossa using the double umbrella device (CardioSEAL) – feasibility and echocardiographic follow-up

Author:

Kaulitz Renate,Peuster Matthias,Jux Christian,Paul Thomas,Hausdorf Gerd

Abstract

Data on long-term follow-up for closure of so-called secundum type“ atrial septal defects within the oval fossa using recently developed devices are limited, and results focused on presence of residual shunting. The purpose of our study was to report the experience from a single center establishing the effectiveness of transcatheter closure in patients with various types of defect other than those located centrally within the oval fossa.A total of 72 patients was included in this study. On transesophageal echocardiography, the size of the defects varied from 6 to 18 mm, with estimation of the stretched diameter from 11 to 21 mm. The ratio of stretched diameter to the extent of the residual septum ranged from 0.28 to 0.54. Mean follow-up was 30.5+ 7.4 months, with a range from 13 to 42 months. The rate of closure using devices with diameters from 28 to 40 mm increased from 80% immediately after implantation to 93% in the 57 patients examined 24 months after implantation. For further analysis, we compared the 44 patients with a solitary, centrally located, defect to 28 having morphological variations, including superiorly located defects with deficient superior and aortic rims, multifenestrated and aneurysmal defects, or isolated additional defects. There was no incidence of formation of thrombus, sustained atrial arrhythmia, or infective endocarditis. Residual shunting was not influenced by location or morphology of the defects, but increased with size, stretched diameter, and the ratio of pulmonary to systemic flows. Serial transthoracic echocardiographic findings revealed malposition of one right-sided superior arm of the device in 8 patients, while protrusion of one leftsided arm onto the right atrial aspect was observed in 3 patients. Fluoroscopy showed fatigue fracture of a single arm in 7 patients (9.7%) within the first 6 months after implantation.These results demonstrate that transcatheter closure with the non self-centering double umbrella device was effective and safe on medium-term follow-up, and could be extended to defects within the oval fossa having various morphologies. Residual shunting resolved with time, and was not related to either morphology or the position of the device.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3