AbstractOcclusion of the atrial septal defects in the oval fossa by interventional catheterization has progressed, but still has limitations. Three-dimensional (3D) echocardiography can provide unique views unavailable by cross-sectional imaging. The objective of this study was to define the clinical application of 3D echocardiography in the assessment and monitoring of transcatheter occlusion of atrial septal defects. Three-dimensional echocardiography was attempted prior to occlusion of atrial septal defects in 41 patients (median age 8.6 years). Serial cross-sectional images were acquired by multiplane transoesophageal echocardiography and displayed by means of computer reconstruction. Dynamic 3D echocardiographic images of defects in the oval fossa were obtained in 40 of 41 patients (98%). Volume-rendering demonstrated the anterosuperior rim in 36 (90%) and the inferoposterior rim in 24 (60%), but failed to reveal small additional fenestrations in six. Sizes measured by 3D echocardiography were significantly larger than those provided by cross-sectional transoesophageal echocardiography (p =;0.007), but differed little from those obtained with balloon sizing (p =; 0.6). After occlusion, 3D echocardiography showed positions of all arms of the device in 20 of 24 cases. Location of any protruding arms, or residual defects, were also clearly revealed.Three-dimensional images obtained in 12 patients during deployment of the double-umbrella device were useful in monitoring its position (single-frame) and for explaining the mechanism of protrusion. Current 3D echocardiography provides clinically relevant information for selection of patients for closure of atrial septal defects by interventional catheterization and when monitoring during implantation. Information obtained by this technique can clarify the mechanism of deployment of the device and closure of the defect, therefore influencing outcomes.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3