Transcatheter occlusion of moderate to large patent arterial ducts, having a diameter above 2.5 mm, with the Amplatzer Duct Occluder. Comparisons with the Rashkind, buttoned devices, and coils in 116 consecutive patients

Author:

Godart François,Rey Christian,Devos Patrick,Brevière Georges-Marie,Francart Charles

Abstract

Aim: To report results of transcatheter occlusion of moderate to large patent arterial ducts, having a minimum diameter above 2.5 mm, with the Amplatzer duct occluder, and to compare these with results achieved using Rashkind or Sideris devices and Cook detachable coils. Design and setting: Retrospective study conducted on intention-to-treat data from a tertiary referral centre. Patients: Since 1989, 116 consecutive patients, 77 females and 39 males, underwent percutaneous closure with several devices. We used the Rashkind double umbrella in 23 patients, the Sideris buttoned device in 39 patients, coils in 17 patients, and the Amplatzer duct occluder in 37 patients. The median age of the patients was 37 months, and the median weight 13 kg. The mean minimum diameter of the duct was 3.8 ± 1.22 mm, with a median of 3.5 mm, and range from 2.5 to 10 mm. Results: Implantation succeeded in all but 9 of the children (92%). The time of fluoroscopy was shorter, and full occlusion was better as judged on angiography, in patients closed using the Amplatzer device, despite closure of larger ducts, than in patients closed using other devices (p < 0.0001, p = 0.0003, and p = 0.0015 for the Rashkind, Sideris, and coils, respectively). Complications included embolisation in 2 patients, and haemolysis in 3 patients. In 12 patients, a second device was inserted because of residual shunting noted during follow-up. Complete occlusion was achieved earlier after implantation (p = 0.0002), and the rate of complete occlusion was better in patients receiving an Amplatzer device (97%, p = 0.024) than in patients undergoing closure with other devices. Conclusion: Transcatheter closure of moderate to large patent arterial ducts using the Amplatzer duct occluder is an effective and safe procedure, providing better results than those achieved using other occluders.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3