Abstract
AbstractWe report a 20-year-old female patient (76 Kg/164 cm) with an extra-cardiac Fontan circulation who was referred to our institution for exertional dyspnoea and desaturation. The patient was diagnosed with a large calcified thrombus at the level of the Fontan fenestration, protruding inside the lumen of the conduit and reducing the diameter by half with a 3 mmHg pressure gradient. Transcatheter stent expansion of the obstructed extra-cardiac conduit was done with a 48 mm long XXL PTFE-covered Optimus-CVS® under temporary cerebral embolic protection with a TriGUARD-3™ deflection filter device (Keystone Heart). There was no procedural complication and the 3 months clinical outcomes are good.
Publisher
Cambridge University Press (CUP)
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献