Effect of Supply Cooling Oil Temperature in Structural Cooling Channels on the Positioning Accuracy of Machine Tools

Author:

Li K.-Y.,Luo W.-J.,Yang M.-H.,Hong X.-H.,Luo S.-J.,Chen C.-N.

Abstract

ABSTRACTIn this study, the thermal deformation of a machine tool structure due to the heat generated during operation was analyzed, and embedded cooling channels were applied to exchange the heat generated during the operation to achieve thermal error suppression. Then, the finite volume method was used to simulate the effect of cooling oil temperature on thermal deformation, and the effect of thermal suppression was experimentally studied using a feed system combined with a cooler to improve the positioning accuracy of the machine tool. In this study, the supply oil temperature in the structural cooling channels was found to significantly affect the position accuracy of the moving table and moving carrier. If the supply oil temperature in the cooling channels is consistent with the operational ambient temperature, the position accuracy of the moving table in the Y direction and the moving carrier in the X and Z directions has the best performance under different feed rates. From the thermal suppression experiments of the embedded cooling channels, the positioning accuracy of the feed system can be improved by approximately 25.5 % during the dynamic feeding process. Furthermore, when the hydrostatic guideway is cooled and dynamic feeding is conducted, positioning accuracy can be improved by up to 47.8 %. The machining accuracy can be improved by approximately 60 % on average by using the embedded cooling channels in this study. Therefore, thermal suppression by the cooling channels in this study can not only effectively improve the positioning accuracy but also enhance machining accuracy, proving that the method is effective for enhancing machine tool accuracy.

Publisher

Oxford University Press (OUP)

Subject

Applied Mathematics,Mechanical Engineering,Condensed Matter Physics

Reference31 articles.

1. 29. Ganesh, K.M. , Kamalesh, N.V. , Dawood, A.K. , Karthikeyan, M. , “CFD Analysis of cooling channels in built-in motorized high speed spindle,” Engineering Science and Technology: An International Journal, 2, pp.238–244 (2012).

2. 28. Renishaw: Interferometry Explained. Available online: http://www.renishaw.com/en/interferometry-explained–7854 (accessed on 13/10/2018)

3. Performance analysis of single-stage air source heat pump utilizing indirect vapor injection design

4. Intelligent High-performance Dynamic Control for Two-stage Screw High-temperature Heat Pump System

5. Development and analysis of a new multi-function heat recovery split air conditioner with parallel refrigerant pipe

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3