Author:
Wang Xiufang,Wang Yu,Liang Yilang,Fan Guangcheng,Nie Xinyi,Yan Zhongming,Xu Qingying
Abstract
Magnetic coupling resonance wireless power transfer technology has attracted worldwide attention in recent years due to its mid-range, non-radiative, and high-efficiency power transfer. However, in regard to its practical applications, there are still some issues that need to be considered and studied with respect to coil design, such as coil structure, and parasitic parameter extraction. This paper investigated the characteristics of magnetic coupling resonance wireless power transfer systems with different coil structures, including circular coils and rectangular coils arranged in parallel. We calculated the magnetic field distributions and mutual inductances by subdividing the receiving coils and computing the magnetic flux density of each subdivision. The proposed analysis was validated by means of the finite element analysis and the experimental results. We investigated the effects of the coil's structure, and topological structures, on the power transfer efficiency. The results demonstrate that using circular coils in parallel is more advantageous than using rectangular coils.
Publisher
Cambridge University Press (CUP)
Subject
Electrical and Electronic Engineering
Cited by
1 articles.
订阅此论文施引文献