L-band radiometer design for long-term stability measurement of one-port devices

Author:

de la Jarrige Emilie Leynia,Escotte Laurent,Gonneau Eric,Goutoule Jean-Marc

Abstract

The design of a high-stability radiometer is presented in this paper. It is used to characterize the stability of a microwave active cold load at L-band. The two-load radiometer takes advantage of a noise injection technique to improve its sensitivity. A temperature-stabilized enclosure is used to minimize gain and noise temperature fluctuations of the receiver. The radiometer sensitivity is 0.031 K and the gain fluctuations are less than 0.005 dB during 1 day. The total gain and the receiver noise temperature of the radiometer exhibit very small variations (<0.03 dB and 1 K, respectively) on the long term.

Publisher

Cambridge University Press (CUP)

Subject

Electrical and Electronic Engineering

Reference31 articles.

1. Sensibilité des radiotélescopes et récepteurs à corrélation;Blum;Ann. Astrophys.,1959

2. An Active "Cold" Noise Source

3. The Measurement of Thermal Radiation at Microwave Frequencies

4. A high stability Ka-band radiometer for tropospheric water vapor measurements;Tanner;IEEE Aerospace Conf.,2001

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Low-Frequency Noise Sources and Gain Stability in Microwave Amplifiers for Radiometry;IEEE Transactions on Microwave Theory and Techniques;2012-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3