Low-frequency pulse-jitter measurement with the uGMRT I: PSR J0437–4715

Author:

Kikunaga TomonosukeORCID,Hisano ShinnosukeORCID,Batra Neelam DhandaORCID,Desai ShantanuORCID,Joshi Bhal Chandra,Bagchi ManjariORCID,Prabu T.ORCID,Takahashi KeitaroORCID,Arumugam Swetha,Bathula AdarshORCID,Dandapat SubhajitORCID,Deb Debabrata,Dwivedi Churchil,Gupta YashwantORCID,Jacob Shebin Jose,Kareem Fazal,Nobleson K.ORCID,Mamidipaka Pragna,Paladi Avinash KumarORCID,Pandian B. ArulORCID,Rana Prerna,Singha JaikhombaORCID,Srivastava AmanORCID,Surnis MayureshORCID,Tarafdar PratikORCID

Abstract

Abstract High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437 $-$ 4715 using data obtained as part of the Indian Pulsar Timing Array experiment. We were able to detect jitter in both the 300–500 MHz and 1 260–1 460 MHz observations of the upgraded Giant Metrewave Radio Telescope (uGMRT). The former is the first jitter measurement for this pulsar below 700 MHz, and the latter is in good agreement with results from previous studies. In addition, at 300–500 MHz, we investigated the frequency dependence of the jitter by calculating the jitter for each sub-banded arrival time of pulses. We found that the jitter amplitude increases with frequency. This trend is opposite as compared to previous studies, indicating that there is a turnover at intermediate frequencies. It will be possible to investigate this in more detail with uGMRT observations at 550–750 MHz and future high-sensitive wideband observations from next generation telescopes, such as the Square Kilometre Array. We also explored the effect of jitter on the high precision dispersion measure (DM) measurements derived from short duration observations. We find that even though the DM precision will be better at lower frequencies due to the smaller amplitude of jitter noise, it will limit the DM precision for high signal-to-noise observations, which are of short durations. This limitation can be overcome by integrating for a long enough duration optimised for a given pulsar.

Publisher

Cambridge University Press (CUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3