A New Quantitative Triage System for Hospitalized Neonates to Assist with Decisions of Hospital Evacuation Priorities

Author:

Imai KazunoriORCID,Suzuki Tomoko,Fukaya Satoko,Karasawa Yuko,Bando Yoko,Sawaki Daisuke,Araki Yuko,Saitoh Shinji,Iwata Osuke

Abstract

AbstractIntroduction:Hospitalized neonates are vulnerable to natural and man-made disasters because of their persistent requirement for medical resources and may need to be evacuated to safe locations when electricity and medical gas supply become unreliable. In Japan, a triage system for hospitalized neonates, or the Simple Triage and Rapid Treatment for Neonates, Revised (START-Neo-R), has been used to determine whether neonates are in suitable conditions for transportation. However, this scale is not useful to determine the evacuation order of neonates because a considerable number of evacuees are classified into the same categories.Study Objective:To solve this problem, a novel triage system, Neonatal Extrication Triage (NEXT) was developed. This study tested the validity and reproducibility of both triages and compared them with a standardized prognostic scoring system for hospitalized neonates, the Neonatal Therapeutic Intervention Scoring System (NTISS).Methods:In this retrospective observational study, physicians and nurses independently assessed each neonate hospitalized at a tertiary neonatal intensive care unit (NICU) twice weekly using NEXT and START-Neo-R. The NEXT system comprises six questionnaires regarding medical resources required during transition and transportation, providing composite scores on a 12-point scale. The START-Neo-R classified neonates into five levels based on the severity of disease and dependence on medical care. Inter-rater reliability of both systems was assessed using Cohen’s kappa coefficient, whereas the criterion validity with NTISS was assessed using Spearman’s correlation coefficient.Results:Overall, 162 neonates were assessed for 49 days, resulting in triage data for 1,079 accumulated patients. Both NEXT scores and START-Neo-R ranks were well-dispersed across different levels without excessive accumulation in specific categories. Inter-rater reliability of NEXT (kappa coefficient, 0.973; 95% confidence interval, 0.969-0.976) and START-Neo-R (kappa coefficient, 0.952; 95% confidence interval, 0.946-0.957) between physicians and nurses was sufficiently high. The correlation coefficient of NEXT and START-Neo-R scores with NTISS scores were 0.889 (P <.001) and 0.850 (P <.001), respectively.Conclusions:Both START-Neo-R and NEXT had good reproducibility and correlation with the severity of neonates indicated by NTISS. With its well-dispersed scores across different levels, the NEXT system might be a powerful tool to determine the priority of evacuation objectively.

Publisher

Cambridge University Press (CUP)

Subject

Emergency Nursing,Emergency Medicine

Reference18 articles.

1. Neonatal Therapeutic Intervention Scoring System: A Therapy-Based Severity-of-Illness Index

2. Triage by Resource Allocation for INpatients: A Novel Disaster Triage Tool for Hospitalized Pediatric Patients

3. 3. The NHS England Emergency Preparedness Framework. Emergency preparedness, resilience and response (EPRR), planning for the shelter and evacuation of people in healthcare settings. https://www.england.nhs.uk/ourwork/eprr. Published 2015. Accessed September 27, 2021.

4. Lessons from the Kumamoto Earthquake: loss of function of a large-scale comprehensive perinatal medical center and emergency evacuation of hospitalized newborn infants;Kawase;J Jpn Pediatr Soc.,2017

5. Nobody likes premies: the relative value of patients’ lives

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3