Endotracheal Tube Cuff Pressure – Comparison of the Two Filling Methods – Simulated Test

Author:

Ilczak TomaszORCID,Ćwiertnia MichałORCID,Białoń PiotrORCID,Szlagor MichałORCID,Kudłacik BeataORCID,Rak MałgorzataORCID,Bialka SzymonORCID,Ubych AdamORCID,Stasicki ArkadiuszORCID,Waksmańska WiolettaORCID,Bujok JanORCID,Mikulska MonikaORCID,Bobiński RafałORCID,Kawecki MarekORCID

Abstract

Abstract Introduction: Tracheal intubation is the optimal method for opening up airways. Performed correctly, it prevents stomach contents from entering the respiratory tract and allows asynchronous cardiopulmonary resuscitation (CPR) to be conducted during sudden cardiac arrest. An important element of correct intubation is proper inflation of the endotracheal tube cuff. Research has shown that when medical personnel use the palpation technique, the cuff is usually inflated incorrectly. This can result in numerous health complications for the patient. Methods: This research was conducted in 2020 on a group of paramedics participating in the 15th International Winter Championship of Medical Rescuers in Bielsko-Biala (Poland). The aim of the research was to assess two methods of inflating the endotracheal tube cuff. Method A involved inflating the cuff using a syringe and assessing the pressure in the control cuff using the palpation technique. Method B involved inflating the cuff using a manometer. During the inflation, both the cuff inflation pressure and the time required to complete the procedure were recorded. Analysis was also conducted on whether completion of certified Advanced Life Support (ALS) and Advanced Cardiovascular Life Support (ACLS) training had any influence on the effectiveness of the inflation procedure. Results: The research showed that paramedics using Method B significantly more often inflated the endotracheal tube cuff to the correct pressure than those using Method A. However, when Method B was used, the procedure took longer to conduct. The study also showed that completion of certified ALS or ACLS training did not have a significant influence on proper inflation of the cuff. Those who had completed certified training courses took significantly longer to inflate the endotracheal tube cuff when using Method A. Conclusions: Inflation of the endotracheal tube cuff by use of a syringe, followed by the palpation technique for assessing the inflation of the cuff balloon, is ineffective. Paramedic teams should be equipped with manometers to be used for inflating the endotracheal tube cuff.

Publisher

Cambridge University Press (CUP)

Subject

Emergency Nursing,Emergency Medicine

Reference20 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3