Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion

Author:

Azapoglu Kaymak BurcuORCID,Eksioglu MerveORCID

Abstract

Abstract Introduction: Handheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance. Objectives: The study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame. Methods: A prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant. Results: Nine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group. Conclusion: Paramedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.

Publisher

Cambridge University Press (CUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3