Evaluation of Bag-Valve-Mask Ventilation by Paramedics in Simulated Chemical, Biological, Radiological, or Nuclear Environments

Author:

Schumacher Jan,Weidelt Lena,Gray Stuart A.,Brinker Andrea

Abstract

AbstractIntroduction:Bag-valve-mask ventilation is a key component of life support, but only one handheld resuscitator is designed to operate in contaminated or toxic atmospheres.Methods:After Institutional Review Board approval, the efficacy of this device was evaluated. The distal trachea of a LaerdalTM Airway Management Trainer was connected to a mechanical Draeger Volumeter 3000TM to enable determination of the minute volume delivered by BVM ventilation. Nineteen paramedics wearing chemical, biological, radiological, or nuclear (CBRN) protective equipment were asked to ventilate this modified airway trainer, either with or without a CBRN filter attached to the inlet filtration system of the AMBUTM Mark III Resuscitator. The maximum levels of minute ventila-tion achieved were compared. Values are given as mean ±SD. A paired t-test was used to detect any differences between the two groups, p-values of <0.05 were defined to show statistical significance.Results:The described model allowed a reproducible and reliable measurement of the delivered minute ventilation. All paramedics were able to operate the device without prior CBRN training. The maximum minute volume achieved without the filter was 9.5 ±2.7 l/min. Use of the inlet CBRN filtra-tion system reduced the maximum minute volume to 6.3 ±2.0 l/min, reduction: 23%. The achieved maximum minute volumes ranged from 15 to 4.9 l/min in the controls and from 9.8 to 1.4 l/min in the CBRN group. Four paramedics were unable to achieve a minute volume >5 l/min in the CBRN group, one participant failed to achieve that value in the control group. The inherent breathing resistance of the CBRN filter appears to reduce the inflow of air into the self-inflatable bag. This delay in refilling may have resulted in a reduced achievable minute volume.Conclusions:The range of maximum minute volumes observed in both groups highlights the need for continuous BVM ventilator training.

Publisher

Cambridge University Press (CUP)

Subject

Emergency Nursing,Emergency Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Suit Up: A Systematic Review of the Personal Protective Equipment (PPE) Recommended and Utilized by Various Classes of Responders to Nuclear Radiological Disasters at Nuclear Power Plants;Prehospital and Disaster Medicine;2024-01-15

2. Medical Response;CBRN and HAZMAT Incidents at Major Public Events;2022-11-10

3. Bibliography;CBRN and HAZMAT Incidents at Major Public Events;2022-11-10

4. An Anesthesiologist’s Perspective on the History of Basic Airway Management;Anesthesiology;2019-05-01

5. Medical Response;CBRN and Hazmat Incidents at Major Public Events;2012-11-30

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3