The adjustment of biological assay results for variation in concomitant observations

Author:

Finney D. J.

Abstract

When individual responses in a biological assay show considerable variation associated with the values of a concomitant variate, covariance analysis may be used in order to adjust the mean responses and to improve the precision of the assay. Usually this is preferable to the choice of an adjustment which involves an arbitrary assumption about the effect of variations in the concomitant variate on the measured response. Published accounts of the process are open to certain theoretical objections, though they may be sufficiently exact for most practical purposes.The present paper describes a method of calculating the relative potency, and its precision, which may be a little more laborious, but which is in full accord with standard statistical practice. The computations are illustrated on data from a prolactin assay by the pigeon crop-gland technique, in which the final crop-gland weight showed a positive correlation with the body weight at the start of the assay. The results are compared with those obtained either from the unadjusted crop-gland weights or from these weights expressed as proportions of body weights. The covariance method leads to a more precise estimate of the potency of the test preparation than do either of the others; there is evidence, however, that the increase in precision will not necessarily be large unless the correlation between the response and the concomitant variate is very close.In a final section, the full statistical tests of assay validity in the covariance analysis are described; these are lengthy, and fortunately are required only when the validity is in considerable doubt.The methods of adjustment have been described in this paper with respect to an assay depending upon parallel regression lines of responses on the logarithms of doses. They may be adapted for use with ‘slope-ratio’ assays (Bliss, 1946; Finney, 1945; 1948; Wood & Finney, 1946), in which the regression of response on dose itself is linear. So far the need for adjusting for concomitant variation in these assays seems not to have arisen, and discussion of computational details may be postponed until the need is felt.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Epidemiology

Reference14 articles.

1. Factorial Design and Covariance in the Biological Assay of Vitamin D

2. A fundamental formula in the statistics of biological assay, and some applications;Fieller;Quart. J. Pharm.,1944

3. The design and statistical analysis of micro-biological assays;Wood;Quart. J. Pharm.,1946

4. The biological assay of insulin. I. Some general considerations directed to increasing the precision of the curve relating dosage and graded response;Bliss;Quart. J. Pharm.,1939

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. REFERENCES;The Statistics of Bioassay;1952

2. A MODIFICATION OF THE METHOD OF DALE AND LAIDLAW FOR STANDARDIZATION OF POSTERIOR PITUITARY EXTRACT;British Journal of Pharmacology and Chemotherapy;1948-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3