Abstract
A sensitive antigen suspension is described for use with a simple slide agglutination method which makes possible a serological diagnosis or exclusion of typhoid fever without recourse to a laboratory. The method has been tested on 414 sera sent to our laboratory; it detected all cases with a titre of 1: 80 or more, and most of those with a titre of 1: 40. The method was further tested on 130 clinically observed cases, in which it gave satisfactory results. The S. A. method gave a positive result with 98 out of 100 sera from patients with typhoid fever, whereas the classical Widal reaction gave a positive result with 68 of them only.The intensity and rapidity of the slide agglutination reaction provide a rough measure of the titre of a serum. A quick and distinct agglutination indicates a titre of 1: 80 or more and is diagnostic of typhoid fever. A slow and indistinct result is obtained when the titre of the serum is about 1: 40. A negative test indicates with great probablity that a diagnosis of typhoid fever may be excluded.We think the method succeeds because the nature of the suspension employed and the peculiar behaviour of slide agglutinations permit the detection of O agglutinins as well as H agglutinins.