Protective isolation in a burns unit: the use of plastic isolators and air curtains

Author:

Lowbury E. J. L.,Babb J. R.,Ford Pamela M.

Abstract

SUMMARYThe use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit.Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator.Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli.Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites.The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3