What Remains to Be Done to Allow Quantitative X-Ray Microanalysis Performed with EDS to Become a True Characterization Technique?

Author:

Gauvin Raynald

Abstract

AbstractThis article reviews different methods used to perform quantitative X-ray microanalysis in the electron microscope and also demonstrates the urgency of measuring the fundamental parameters of X-ray generation for the development of accurate standardless quantitative methods. Using ratios of characteristic lines acquired on the same X-ray spectrum, it is shown that the Cliff and LorimerKA-Bfactor can be used in a general correction method that is appropriate for all types of specimens and electron microscopes, providing that appropriate corrections are made for X-ray absorption, fluorescence, and indirect generation. Since the fundamental parameters appear in theKA-Bfactor, only the ratio of the ionization cross sections needs to be known, not their absolute values. In this regard, the measurement of ratios of theKA-Bfactor (or intensities at different beam energies of the same material with no change of beam spreading in the material) permits the validation for the best models to compute the ratio of ionization cross sections. It is shown, using this method, that the nonrelativistic Bethe equation, to compute ionization cross section, is very close to the equation of E. Casnati et al. (J Phys B15, 155–167, 1982) and also to the equations proposed by D. Bote and F. Salvat (Phys Rev A77, 042701, 2008) for the computation of the ratio of ionization cross sections. The method is extended to show that it could be used to determine the values of the Coster-Kronig transitions factors, an important fundamental parameter for the generation of L and M lines that is mostly known with poor accuracy. The detector efficiency can be measured with specimens where their intensities were measured with an energy dispersive spectrometer detector, the efficiency of which has been measured in an X-ray synchrotron (M. Alvisi et al.,Microsc Microanal12, 406–415, 2006). The spatial resolution should always be computed when performing quantitative X-ray microanalysis and the equations of R. Gauvin (Microsc Microanal13(5), 354–357, 2007) for bulk materials and the one presented in this article for thin films should be used. The effects of X-rays generated by fast secondary electrons and by Auger electrons are reviewed, and their effect can be detrimental for the spatial resolution of materials involving low-energy X-ray lines, in certain specific conditions. Finally, quantitative X-ray microanalysis of heterogeneous materials is briefly reviewed.

Publisher

Cambridge University Press (CUP)

Subject

Instrumentation

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3