Author:
McDermott Michael W.,Ciricillo Samuel F.,Gutin Philip H.,Edwards Michael S.B.
Abstract
AbstractBackgroundStereotactic insertion of catherters into deep-seated tumors or developmental cysts is easily accomplished, but connecting the catheter to an Ommaya reservoir while maintaining catheter position can be difficult. We describe a technique for easy placement of a catheter-Ommaya reservoir construct with one pass.MethodsStandard stereotactic imaging is performed. The distance from the outer table of the skull to the target point is measured. A catheter-Ommaya reservoir construct is assembled to this length and directed to the target position with a standard Cosman-Robert-Wells (CRW) stereotactic frame.ResultsUse of this technique placed catheters into tumor or developmental cysts accurately and with no surgical complications in 12 patients.ConclusionsThis technique is simple, safe, reliable, and requires no special equipment. It avoids the risk of dislodging the catheter when it is being connected to the Ommaya reservoir, reducing the chances of cyst leakage and collapse.
Publisher
Cambridge University Press (CUP)
Subject
Neurology (clinical),Neurology,General Medicine
Cited by
10 articles.
订阅此论文施引文献