Abstract

Background: Wagner proximal femur prosthesis is the versatile modular implant. Study Design: Prospective study Setting: Department of Orthopaedic Surgery Dow University of Health Sciences / Civil Hospital Karachi, from January 2013 to December 2019. Methodology: Total 19 patients of both genders with proximal femur bone loss due to tumor, implant failure for proximal femur fixation, comminuted intertrochanteric fracture, and failed arthroplasty included in the study. After taking written informed consent, detailed demographics including age, gender, indication of wagner prosthesis, and wagner stem type were recorded. Among all the patients 11 patients received total hip replacement and 8 patients received bipolar. Complications associated with procedure were recorded. Outcomes were assessed by Merle D Aubgine scale. Results: Total 19 patients were included in the study who were operated with wagner prosthesis for proximal femur bone deficit problems. 7 (37%) patients were male and 12 (67%) were female , between age of 16 to 70. 13 (68%) patient have proximal femur problem on right side and 6(32%) patient on left side .10 Patient have proximal femur fixation problems and 9 with proximal femur tumor. Modular wagner prosthesis used in all patients . Per-operative one (5%) patient have perforation of cortex and One (5%)patient posterior hip dislocation on next day . Two (11%) patient had per-operative fracture . Maximum follow-up is from 6.3 years to minimum 6 months. One patient with metastasis died within four weeks of surgery. Outcome measured with modified Merle D Aubgine scale showed no excellent , good in 15(79%) , fair 3 (16%), poor 1(5%). Conclusion: Wagner proximal femur modular implant is a versatile implant for proximal femur fixation failure and after proximal femur resection in tumor patients. It is modular with variable options to make stable hip joint. It is cheap as comparative to proximal femur replacement implant for tumor. Keywords: Implant failure, Proximal femur, Tumor, Wagner implant.

Publisher

Lahore Medical and Dental College

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3