Approximation of Pediatric Morphometry for Resuscitative Endovascular Balloon Occlusion of the Aorta
-
Published:2019-09-04
Issue:3
Volume:3
Page:
-
ISSN:2002-7567
-
Container-title:Journal of Endovascular Resuscitation and Trauma Management
-
language:
-
Short-container-title:JEVTM
Author:
DeSoucy Erik Scott,Trappey Alfred Francois,Wishy Andrew M,Simon Meryl A,Davidson Anders J,DuBose Joseph J,Johnson Michael Austin,Williams Timothy K
Abstract
Background
Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) may be beneficial in the management of traumatic and iatrogenic vascular and solid organ injuries in children, but requires an understanding of vessel diameter at the access site and landing zones. We sought to adapt the Broselow™ Tape method to estimation of aortic and femoral artery diameters for this purpose.
Methods
Computed tomography scans from trauma and non-trauma pediatric patients at a level 1 trauma center were reviewed for vascular dimensions at aorta Zone I, Zone III and the common femoral artery (CFA). Vessel size was measured by two providers using a vascular software suite with a 10% interobserver comparison. Height was used to create linear regression equations for each location and calculate ranges for each Broselow™ Tape category.
Results
We reviewed scans from 110 patients ages 2-14 years with less than 8% interobserver variability. 64% were male and 46% were trauma patients. Height based regression equations were closely correlated with vessel diameter:
Zone I(mm)=[0.093±0.006·height(cm)]+0.589±0.768; R2=0.714, p<0.001
Zone III(mm)=[0.083±0.005·height(cm)]–0.703±0.660; R2=0.728, p<0.001
CFA(mm)=[0.043±0.003·height(cm)]+0.644±0.419; R2=0.642, p<0.001
These equations, along with the minimum and maximum length for each Broselow™ Tape color, were used to define color coded normal ranges for each REBOA landing zone and access site.
Conclusion
Knowledge of the access vessel and occlusion zone diameters in pediatric patients is crucial for future research and application of REBOA in this population. Furthermore, an adapted Broselow™ Tape including these measurements would assist in appropriate sheath and balloon catheter selection in emergent settings.
Publisher
Orebro Univeirsty Hospital, EVTM Program
Subject
Critical Care and Intensive Care Medicine,Emergency Medicine,Surgery
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献