A FUNDAMENTAL STUDY ON NONLINEAR ANALYSIS FOR PREDICTION USING SDOF MODEL OF HEAVY-WEIGHT FLOOR IMPACT SOUND LEVEL REDUCTION WITH THE CAR TIRE FOR DRY FLOATING FLOOR STRUCTURE IN THE LABORATORY
-
Published:2024-09-01
Issue:823
Volume:89
Page:526-537
-
ISSN:1348-0685
-
Container-title:Journal of Environmental Engineering (Transactions of AIJ)
-
language:en
-
Short-container-title:Journal of Environmental Engineering (Transactions of AIJ)
Author:
ISHIMARU Takeshi1, NISHIKAWA Yoshio2, OWAKI Masanao3, KUROKI Taku3, KUME Satoshi1, TAKANE Yuki1
Affiliation:
1. Taisei Co., Ltd. 2. National Institute of Technology (KOSEN), NAGANO College 3. Technical Research & Development Institute Kumagai Gumi Co., Ltd.
Publisher
Architectural Institute of Japan
Reference16 articles.
1. 1) ISO 16283-2, Acoustics- Field measurement of sound insulation in buildings and of building elements- Part2 : Impact sound and insulation, 2018.5 ISO16283-2, 音響- 建築物及び建築部材の遮音性能の現場における測定方法-第 2 部-床衝撃音遮断性能, 2018.5 2. 2) Koga T., Tano M., Andow Kei.: Air Spring effect for improvement of heavy impact sound of the wooden cover floor on concreate slab, Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ), No.546, pp.9-14, 2001.8(in Japanese) DOI: https://doi.org/10.3130/aija.66.9_6 古賀貴士, 田野正典, 安藤啓:コンクリートスラブ上に設置された木質系二重床の重量床衝撃音改善量に対する空気ばねの影響に関する実験的研究, 日本建築学会計画系論文集, 第 546 号, pp.9-14, 2001.8 3. 3) Ishimaru T., Owaki M., Takakura F.,Zaima T., Kume S., Yamashita Y.,: Influence on vibration propagation characteristic of the dry double floorings by the difference of the impulsive force- A study on heavy weight floor impact sound insulation performance of the dry double flooring in multiple dwelling houses-, AIJ Journal of Technology and Design, Vol.13, No.26, pp.585-589, 2007.12(in Japanese) DOI: https://doi.org/10.3130/aijt.13.585 石丸岳史, 大脇雅直, 高倉史洋, 財満健史, 久米智史, 山下恭弘 : 衝撃力の違いが乾式二重床上の振動伝搬特性に及ぼす影響に関する検討-集合住宅に用いられる乾式二重床の重量床衝撃音遮断性能に関する研究-, 日本建築学会技術報告集, 第 13 巻, 第 26 号, pp.585-589, 2007.12 4. 4) Shikakura J., Inoue K., Amakawa K., Ohkawa S., Ohkawa H. : Compatibility of floor impact sound level by change of heavy impact source, AIJ Journal of Technology and Design, Vol.23, No.53, pp.171-176, 2017.2(in Japanese) 鹿倉潤二, 井上勝夫, 天川恭一, 大川周一郎, 大川平一郎:重量衝撃源の変化による床衝撃音レベルの互換性に関する検討, 日本建築学会技術報告集 第23 巻, 第 53 号, pp.171-176, 2017.2 5. 5) Masuda K., Tanaka H., : Study on changes in heavy impact sound level reduction of a double floor using finite difference method with nonlinear three-degree-of-freedom system, Journal of Architectural acoustics and noise control, No.185(vol.48), pp.72-78, 2019.3(in Japanese) 増田潔, 田中ひかり:非線形 3 自由度モデル差分法を用いた乾式二重床の重量床衝撃音レベル低減量の変化に関する検討, 音響技術, No.185(vol.48), pp.72-78, 2019.3
|
|