Safety, acceptability, and pharmacokinetics of a monoclonal antibody-based vaginal multipurpose prevention film (MB66): A Phase I randomized trial

Author:

Politch Joseph A.ORCID,Cu-Uvin Susan,Moench Thomas R.,Tashima Karen T.,Marathe Jai G.,Guthrie Kate M.ORCID,Cabral HowardORCID,Nyhuis Tara,Brennan Miles,Zeitlin LarryORCID,Spiegel Hans M. L.ORCID,Mayer Kenneth H.ORCID,Whaley Kevin J.ORCID,Anderson Deborah J.

Abstract

Background MB66 film is a multipurpose prevention technology (MPT) product with monoclonal antibodies (mAbs) against HIV-1 (VRC01-N) and HSV-1 and 2 (HSV8-N). The mAbs were produced by transient expression in Nicotiana benthamiana (N). We conducted a Phase I clinical trial to assess the safety, pharmacokinetics (PK), and ex vivo efficacy of single and repeated doses of MB66 when used intravaginally. Methods and findings The clinical trial enrolled healthy reproductive-aged, sexually abstinent women. In Segment A, 9 women received a single MB66 film which was inserted into the vaginal posterior fornix by a clinician. In Segment B, 29 women were randomly assigned to MB66 (Active) or Placebo film groups and were instructed to insert 1 film vaginally for 7 consecutive days. Visits and clinical sampling occurred predose and at various time points after single and repeated film doses. The primary endpoint was number of adverse events (AEs) Grade 2 or higher related to product use. Secondary endpoints included film dissolution rate, Nugent score (a Gram stain scoring system to diagnose bacterial vaginosis), vaginal pH, post-use survey results, cytokine concentrations in cervicovaginal lavage (CVL) specimens (assessed by Luminex assay), mAb concentrations in vaginal fluid collected from 4 sites (assessed by ELISA), and HIV and HSV neutralization activity of CVL samples ex vivo (assessed by TZM-bl and plaque reduction assay, respectively). The product was generally safe and well tolerated, with no serious AEs recorded in either segment. The AEs in this study were primarily genitourinary in nature with the most commonly reported AE being asymptomatic microscopic hematuria. There were no differences in vaginal pH or Nugent scores or significant increases in levels of proinflammatory cytokines for up to 7 days after film insertion in either segment or between Active and Placebo groups. Acceptability and willingness to use the product were judged to be high by post-use surveys. Concentrations of VRC01-N and HSV8-N in vaginal secretions were assessed over time to generate pharmacokinetic curves. Antibody levels peaked 1 hour postdosing with Active film (median: 35 μg/mL) and remained significantly elevated at 24 hours post first and seventh film (median: 1.8 μg/mL). Correcting for sample dilution (1:20), VRC01-N concentrations ranged from 36 to 700 μg/mL at the 24-hour time point, greater than 100-fold the IC50 for VRC01 (0.32 μg/mL); HSV8-N concentrations ranged from 80 to 601 μg/mL, well above the IC50 of 0.1 μg/m. CVL samples collected 24 hours after MB66 insertion significantly neutralized both HIV-1 and HSV-2 ex vivo. Study limitations include the small size of the study cohort, and the fact that no samples were collected between 24 hours and 7 days for pharmacokinetic evaluation. Conclusions Single and repeated intravaginal applications of MB66 film were safe, well tolerated, and acceptable. Concentrations and ex vivo bioactivity of both mAbs in vaginal secretions were significantly elevated and thus could provide protection for at least 24 hours postdose. However, further research is needed to evaluate the efficacy of MB66 film in women at risk for HIV and HSV infection. Additional antibodies could be added to this platform to provide protection against other sexually transmitted infections (STIs) and contraception. Trial registration ClinicalTrials.gov NCT02579083.

Funder

National Institute of Allergy and Infectious Diseases

Publisher

Public Library of Science (PLoS)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3