The role of intraoperative microelectrode recording and stimulation in subthalamic lead placement for Parkinson’s disease

Author:

Malinova VesnaORCID,Pinter Anabel,Dragaescu Cristina,Rohde Veit,Trenkwalder Claudia,Sixel-Döring Friederike,von Eckardstein Kajetan L.

Abstract

Objective Intraoperative microelectrode recording (MER) and test-stimulation are regarded as the gold standard for proper placement of subthalamic (STN) deep brain stimulation (DBS) electrodes in Parkinson’s disease (PD), requiring the patient to be awake during the procedure. In accordance with good clinical practice, most attending neurologists will request the clinically most efficacious trajectory for definite lead placement. However, the necessity of microelectrode-test-stimulation is disputed, as it may limit the access to DBS therapy, excluding those not willing or incapable of undergoing awake surgery. Methods We retrospectively analyzed the MERs and microelectrode-test-stimulation results with regard to the decision on definite lead placement and clinical outcome in a cohort of 67 PD-patients with STN-DBS. All patients received bilateral quadripolar ring electrodes. To ascertain overall procedural efficacy, we calculated the surgical index (SI) by comparing preoperative motor improvement induced by levodopa to that induced by stimulation 7 to 18 months after surgery, measured as the relative difference between ON and OFF-states on the Unified Parkinson’s Disease Rating Scale motor part (UPDRS-3). Additionally, a side-specific surgical index (SSSI) was calculated using the unilateral assessable items of the UPDRS-3. The SSSI where microelectrode-test-stimulation overruled MER were compared to those where the result of microelectrode-test-stimulation was congruent to MER results. Results A total of 134 electrodes were analyzed. For final lead placement, the central trajectory was chosen in 54% of patient hemispheres. The mean SI was 0.99 (± 0.24). SSSI averaged 1.04 (± 0.45). In 37 lead placements, microelectrode-test-stimulation overruled MER in the final trajectory selection, in 27 of these lead placements adverse effects during microelectrode-test-stimulation were decisive. Neither the number of test electrodes used nor the STN-signal length had an impact on the SSSI. The SSSI did not differ between lead placements with MER/microelectrode-test-stimulation congruency and those where the results of microelectrode-test-stimulation initiated lead placement in a trajectory with shorter STN signal. Conclusion Intraoperative testing is mandatory to ensure an optimal motor outcome of STN DBS in PD-patients when using quadripolar ring electrodes. However, we also demonstrated that neither the length of the STN-signal on MER nor the number of test electrodes influenced the motor outcome.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3