A total blood volume or more transfused during pregnancy or after childbirth: Individual patient data from six international population-based observational studies

Author:

McCall Stephen J.ORCID,Henriquez Dacia,Edwards Hellen McKinnon,van den Akker Thomas,Bloemenkamp Kitty W. M.,van der Bom Johanna,Bonnet Marie-PierreORCID,Deneux-Tharaux Catherine,Donati Serena,Gillissen Ada,Kurinczuk Jennifer J.ORCID,Li Zhuoyang,Maraschini Alice,Seco Aurélien,Sullivan Elizabeth,Stanworth Simon,Knight Marian

Abstract

Background This study aimed to compare incidence, management and outcomes of women transfused their blood volume or more within 24 hours during pregnancy or following childbirth. Methods Combined analysis of individual patient data, prospectively collected in six international population-based studies (France, United Kingdom, Italy, Australia, the Netherlands and Denmark). Massive transfusion in major obstetric haemorrhage was defined as transfusion of eight or more units of red blood cells within 24 hours in a pregnant or postpartum woman. Causes, management and outcomes of women with massive transfusion were compared across countries using descriptive statistics. Findings The incidence of massive transfusion was approximately 21 women per 100,000 maternities for the United Kingdom, Australia and Italy; by contrast Denmark, the Netherlands and France had incidences of 82, 66 and 69 per 100,000 maternities, respectively. There was large variation in obstetric and haematological management across countries. Fibrinogen products were used in 86% of women in Australia, while the Netherlands and Italy reported lower use at 35–37% of women. Tranexamic acid was used in 75% of women in the Netherlands, but in less than half of women in the UK, Australia and Italy. In all countries, women received large quantities of colloid/crystalloid fluids during resuscitation (>3·5 litres). There was large variation in the use of compression sutures, embolisation and hysterectomy across countries. There was no difference in maternal mortality; however, variable proportions of women had cardiac arrests, renal failure and thrombotic events from 0–16%. Interpretation There was considerable variation in the incidence of massive transfusion associated with major obstetric haemorrhage across six high-income countries. There were also large disparities in both transfusion and obstetric management between these countries. There is a requirement for detailed evaluation of evidence underlying current guidance. Furthermore, cross-country comparison may empower countries to reference their clinical care against that of other countries.

Funder

Medical Research Foundation

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference38 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3