Variability of tissue mechanical response in Sus Domesticus porcine models from in vivo to ex vivo conditions

Author:

Malik Faizan A.ORCID,Drahos Bradley A.ORCID,Safdari Amer M.ORCID,Mazzeo Mark V.,Norfleet Jack E.,Sweet Robert M.,Kowalewski Timothy M.ORCID

Abstract

Background Healthcare simulators have been demonstrated to be a valuable resource for training several technical and nontechnical skills. A gap in the fidelity of tissues has been acknowledged as a barrier to application for current simulators; especially for interventional procedures. Inaccurate or unrealistic mechanical response of a simulated tissue to a given surgical tool motion may result in negative training transfer and/or prevents the “suspension of disbelief” necessary for a trainee to engage in the activity. Thus, where it is relevant to training outcomes, there should be an effort to create healthcare simulators with simulated tissue mechanical responses that match or represent those of biological tissues. Historically, this data is most often gathered from preserved (post mortem) tissue; however, there is a concern that the mechanical properties of preserved tissue, that lacks blood flow, may lack adequate accuracy to provide the necessary training efficacy of simulators. Methods and findings This work explores the effect of the “state” of the tissue testing status on liver and peritoneal tissue by using a customized handheld grasper to measure the mechanical responses of representative porcine (Sus domesticus) tissues in n = 5 animals across five test conditions: in vivo, post mortem (in-situ), ex vivo (immediately removed from fresh porcine cadaver), post-refrigeration, and post-freeze-thaw cycle spanning up to 72 hours after death. No statistically significant difference was observed in the mechanical responses due to grasping between in vivo and post-freeze conditions for porcine liver and peritoneum tissue samples (p = 0.05 for derived stiffness at grasping force values F = 5N and 6.5N). Furthermore, variance between in vivo and post-freeze conditions within each animal, was comparable to the variance of the in vivo condition between animals. Conclusions Results of this study further validate the use of preserved tissue in the design of medical simulators via observing tissue mechanical responses of post-freeze tissue comparable to in vivo tissue. Therefore, the use of thawed preserved tissue for the further study and emulation of mechanical perturbation of the liver and peritoneum can be considered. Further work in this area should investigate these trends further, particularly in regard to other tissues and the potential effects varying preservation methods may yield.

Funder

Army Research Laboratory

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference7 articles.

1. Biomechanical Properties of Abdominal Organs In Vivo and Postmortem Under Compression Loads;J Rosen;J Biomech Eng,2008

2. Mechanical properties of the human uterine cervix: An in vivo study;E Mazza;Med Image Anal,2006

3. Effect of Preservation Period on the Viscoelastic Material Properties of Soft Tissues With Implications for Liver Transplantation;S. Ocal;J Biomech Eng,2010

4. Effects of perfusion on the viscoelastic characteristics of liver;AE Kerdok;J Biomech,2006

5. Measuring In Vivo Animal Soft Tissue Properties for Haptic Modeling in Surgical Simulation;I Brouwer;Medicine Meets Virtual Reality,2001

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Thawed Porcine Model for Surgical Training: A Novel Conservative Procedure;Journal of Laparoendoscopic & Advanced Surgical Techniques;2024-01-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3