Detecting and monitoring dental plaque levels with digital 2D and 3D imaging techniques

Author:

Giese-Kraft KatjaORCID,Jung Katja,Schlueter Nadine,Vach Kirstin,Ganss Carolina

Abstract

Detecting and monitoring dental plaque is an important issue in research and clinical practice. In this context, new digital imaging methods that permit permanent documentation of the clinical findings could be promising tools. The aim of the study was therefore to investigate whether disclosed plaque can be reliably visualised on 2D and 3D images captured with digital intraoral imaging devices. Clinical examination was the reference method. Twenty subjects (27.5±1.2 years) were included and plaque was measured at three different stages: habitual plaque (T1), after 72 h without oral hygiene (T2) and after a subsequent habitual brushing exercise (T3). At each time point, plaque was disclosed followed by the clinical examination and capturing the 2D and 3D images (intraoral-camera CS 1500 and intraoral-scanner CS 3600; Carestream Dental, Germany). Plaque amounts were recorded on oral and vestibular surfaces of the Ramfjord-teeth (16, 21, 24, 36, 41, 44) using the Rustogi-modified-Navy-Plaque-Index (RMNPI) and expressed as percentage of plaque-containing RMNPI areas of all RMNPI areas. At T1, percentages (mean±SD) obtained from the clinical examination, 2D and 3D images were 62.2±10.6, 65.1±10.0 and 64.4±10.6 resp. increasing to 76.9±8.0, 77.9±8.6 and 77.5±9.4 resp. at T2. After toothbrushing (T3), values decreased to 56.3±11.1, 58.2±12.1 and 61.2±10.8 resp. All methods were able to show statistically significant changes in plaque amounts at the different time points with in part statistically significant but minor differences between them. The Bland-Altmann analysis revealed a good agreement between values from both 2D and 3D images with the clinical examination. The agreement of the scores obtained with the both image-based methods for the single RMNPI areas with the clinical examination was mainly classified as substantial to almost perfect. Amounts of plaque can be reliably detected and monitored on 2D images from an intraoral camera and on 3D images from an intraoral scanner.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3