Using standard-length compactors to implant short humeral stems in total shoulder arthroplasty: A cadaver study of humeral stem alignment

Author:

Gunst StanislasORCID,Nigues Ana,Vogels Jérôme,Servien Elvire,Lustig Sébastien,Nove-Josserand Laurent,Collotte Philippe

Abstract

Background Short-stem implants in shoulder arthroplasty were recently developed and reported clinical outcomes are good. However, radiological analysis often reveals humeral stem misalignment in the frontal plane, along with high filling ratios that can lead to proximal bone remodeling under stress shielding. The aim of this cadaveric study was to test whether using compactors for standard-length (> 100 mm) stems to implant short (< 100 mm) stems reduces the risk of stem misalignment without compromising in terms of a higher filling ratio. Methods In a cadaveric study, twenty short stems were implanted using instrumentation for standard-length stems. Alignment and filling ratios were evaluated on anteroposterior radiographs for both the compactors and the stems. The angular deviations (α) from the humeral axis of the compactors and the short stems were measured. Misalignment was defined as |α| > 5°. Metaphyseal and diaphyseal filling ratios were calculated and defined as either high (≥ 0.7) or low (< 0.7). Results The median angular deviations of the compactors and the short stems were respectively 1.6° (range, 0.03 to 5.9°) and 1.3° (range, 0.3 to 9.6°). Nineteen of the 20 compactors (95%) and 17/20 short stems (85%) were correctly aligned. The proportions of correctly aligned compactors and stems were not significantly different (95% CI, −0.33 to 0.11; Z-test of proportions p = .60), and the respective angular deviations were significantly correlated (Spearman ρ = .60, p = 0.006). The diaphyseal and metaphyseal filling ratios of the compactors and the stems were all low. Conclusions In this series of 20 implants in cadavers, the narrow short humeral stems implanted with compactors for standard-length stems were correctly aligned with the humeral axis. This approach may be a way to achieve both correct frontal alignment and low filling ratios.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3