The utility of extended differential parameters as a biomarker of bacteremia at a tertiary academic hospital in persons with and without HIV infection in South Africa

Author:

Lemkus Lauren,Lawrie Denise,Vaughan JeniferORCID

Abstract

Introduction Extended differential parameters (EDPs) are generated with the automated differential count by Sysmex XN-series automated hematology analysers, and include the immature granulocyte count (IG%), the neutrophil fluorescent light intensity (NE-SFL) and the neutrophil fluorescent light distribution width (NE-WY). These have been proposed as early biomarkers of bacteremia. This study aimed to evaluate the NE-SFL, NE-WY and IG% in comparison to neutrophil CD64 (nCD64) expression (as a high quality sepsis biomarker) among patients with suspected bacterial sepsis at the Chris Hani Baragwanath Academic Hospital in Johannesburg, South Africa. Methods A daily search of the laboratory information system identified samples submitted for a blood culture (BC) and a concurrent full blood count (FBC). Automated differential counts using a Sysmex XN-9000 haematology analyser and neutrophil CD64 expression by flow cytometry were assessed on the residual FBC samples. Results A total of 151 samples were collected, of which 83 were excluded due to equivocal results with regards to the presence of bacterial infection. The remaining 68 samples included 23 with bacteremia, 28 with evidence of non-bacteremic bacterial infection, 13 with no evidence of bacterial infection and 4 with Tuberculosis. HIV status was documented in 90 of the patients, with a seropositivity rate of 57.8%. The EDPs were all significantly higher among patients with bacteremia as compared to those without bacterial infection, but on ROC curve analyses, only the NE-SFL showed good performance (AUC>0.8) for discriminating cases with bacteremia from those without bacterial infection at a cut-off value of 49.75. In comparison to the nCD64, the NE-SFL showed moderate agreement (kappa = 0.5). On stratification of the ROC analysis by HIV status, the NE-SFL showed superior performance among persons with HIV infection (AUC = 1), while the automated IG% showed better performance among the patients without HIV infection (AUC = 0.9). Conclusion In this study, EDPs showed differential performance as biomarkers for bacteremia according to HIV-status in the South African setting, with the most promising results seen with the NE-SFL and IG% parameters among people with and without HIV infection, respectively. Further assessment of these parameters without pre-selection of patients likely to have infection is required to further determine their clinical utility, particularly among patients with underlying inflammatory conditions or malignancy.

Funder

National Health Laboratory Services Research Trust

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3