Remote assessment of DMFT and number of implants with intraoral digital photography in an elderly patient population – a comparative study

Author:

Ciardo AntonioORCID,Sonnenschein Sarah K.,Simon Marlinde M.,Ruetters Maurice,Spindler Marcia,Ziegler Philipp,Reccius Ingvi,Spies Alexander-Nicolaus,Kykal Jana,Baumann Eva-Marie,Fackler Susanne,Büsch Christopher,Kim Ti-Sun

Abstract

Objectives This comparative study aimed to evaluate intraoral digital photography (IODP) as assessment-tool for DMFT and number of implants (IMPL) compared to clinical diagnosis (CLIN) in an elderly population with high restorative status. Secondary research questions were whether an additional evaluation of panoramic radiographs (PAN-X) or raters’ clinical experience influence the agreement. Methods Fifty patients (70.98±7.60 years) were enrolled for standardized CLIN and IODP. The clinical reference examiner and ten blinded raters evaluated the photographs without and with a PAN-X regarding DMFT and IMPL. CLIN were used as reference standard and differences to IODP and IODP-PAN-X findings were analysed descriptively. To assess intra-rater agreement, pairwise Gwet’s AC1s of the three diagnostic methods CLIN, IODP and IODP+PAN-X were calculated. Results Compared to a DMFT of 22.10±3.75 (CLIN), blinded raters evaluated a DMFT of 21.54±3.40 (IODP) and 22.12±3.45 (IODP+PAN-X). Mean values for “Decayed” were 0.18±0.52 (CLIN), 0.45±0.46 (IODP) and 0.48±0.47 (IODP-PAN-X), while 11.02±5.97 (CLIN), 10.66±5.78 (IODP) and 10.93±5.91 (IODP+PAN-X) were determined for “Missing” and 10.90±5.61 (CLIN), 10.43±4.85 (IODP) and 10.71±5.11 (IODP+PAN-X) for “Filled”. IMPL were 0.78±2.04 (CLIN), 0.58±1.43 (IODP), 0.78±2.04 (IODP+PAN-X). Gwet’s AC1 using the mode of the blinded raters’ assessment of "Decayed", "Missing" and IMPL compared to CLIN ranged from 0.81 to 0.89 (IODP) and 0.87 to 1.00 (IODP+PAN-X), while for "Filled" and DMFT they were 0.29 and 0.36 (IODP) as well as 0.33 and 0.36 (IODP+PAN-X), respectively. Clinical experience did not influence the agreement. Conclusions Assessment of “Decayed”, “Missing” and IMPL by IODP showed almost perfect agreement, whereas of “Filled” and DMFT revealed fair to moderate agreement with clinical findings. Additional PAN-X-evaluation increased agreement compared to IODP-diagnostics alone. IODP for the assessment of DMFT and IMPL might be a suitable method in large-scale epidemiological studies, considering high agreement in total values and miscellaneous agreement at patient-level.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3