Effects of different stent wire mesh densities on hemodynamics in aneurysms of different sizes

Author:

Masuda Shunsuke,Fujimura Soichiro,Takao HiroyukiORCID,Takeshita Kohei,Suzuki TakashiORCID,Uchiyama YuyaORCID,Karagiozov Kostadin,Ishibashi Toshihiro,Fukudome Koji,Yamamoto MakotoORCID,Murayama Yuichi

Abstract

Background Intracranial stents are used to treat aneurysms by diverting the blood flow from entering into the aneurysmal dome. Although delayed rupture is rare, clinical outcomes are extremely poor in such cases. Hemodynamics after stent deployment may be related to delayed rupture and a better understanding of the basic characteristics of pressure changes resulting from stent deployment is needed; therefore, this study investigated the relationships between hemodynamics in aneurysms of different sizes treated using stents of different wire mesh densities. Methods Using computational fluid dynamics analysis, parameters related to velocity, volume flow rate, pressure, and residual volume inside the aneurysm were evaluated in digital models of 5 basic aneurysms of differing sizes (Small, Medium, Medium-Large, Large, and Giant) and using 6 different types of stent (varying number of wires, stent pitch and wire mesh density) for each aneurysm. Results Regardless of the aneurysm size, the velocity inside the aneurysm and the volume flow rate into the aneurysm were observed to continuously decrease up to 89.2% and 78.1%, respectively, with increasing stent mesh density. In terms of pressure, for giant aneurysms, the pressure on the aneurysmal surface elevated to 10.3%, then decreased to 5.1% with increasing stent mesh density. However, in smaller aneurysms, this pressure continuously decreased with increasing stent mesh density. The flow-diverting effect of the stents was limited when a stent with low mesh density (under 20%) was used with a giant aneurysm. Conclusions The present results indicate that the selection of appropriate stents according to aneurysm size may contribute to reduced risks of hemodynamic alternations related to stent deployment, which could reduce the incidence of delayed rupture.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3