Preclinical safety evaluation of continuous UV-A lighting in an operative setting

Author:

Guenter RachaelORCID,Zheng-Pywell Rui,Herring Brendon,Murphy Madisen,Foote JeremyORCID,Benner KevinORCID,Rose J. BartORCID

Abstract

Background Germicidal ultraviolet (UV-C) light has been shown as an effective modality for disinfection in laboratory settings and in the operative room. Traditionally, short-wavelength UV-C devices, which have previously been shown to cause DNA damage, are utilized only for disinfection in pre- and post-operative settings and are not continuously active during operations. Continuous use of intraoperative UV light has potential to decrease pathogens and subsequent surgical site infections (SSIs), which arise in approximately 5–15% of operative cases. SSIs are a significant determinant of patient morbidity, readmission rates, and overall cost. Therefore, a method of UV light disinfection with a low risk of DNA damage is needed so that greater antimicrobial protection can be afforded to patients during the entirety of their surgical procedures. A new disinfection device that harnesses longer-wavelength UV-A light to disinfect the surgical field throughout the entirety of the procedure, including pre- and post-operation has been developed. Methods This study aimed to determine if UV-A light administered intraoperatively was safe, as defined by the minimal presence of DNA damage and safe amounts of reflection upon medical personnel. Using in vitro models, we examined the differential impacts of UV-C and UV-A light on DNA damage and repair pathways. In a murine model, we looked at the production of DNA damage photoproduction in relation to UV-A versus UV-C exposure. Results Our results show UV-A light does not induce a significant amount of DNA damage at the cellular or tissue level. Furthermore, a preclinical porcine study showed that surgical personnel were exposed to safe levels of UV-A irradiance from an overhead UV-A light used during an operation. The amount of UV-A transmitted through surgical personal protective equipment (PPE) also remained within safe levels. Conclusions In conclusion, we found that UV-A may be safe for intraoperative use.

Funder

GE Current, a Daintree company

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference49 articles.

1. Evidence-based Prevention of Surgical Site Infection.;MA Fuglestad;Surg Clin North Am. United States,2021

2. Surgical site infections.;PY Young;Surg Clin North Am. United States;,2014

3. Impact of surgical site infection on healthcare costs and patient outcomes: a systematic review in six European countries.;JM Badia;J Hosp Infect. England,2017

4. Evidence update on prevention of surgical site infection.;D Leaper;Curr Opin Infect Dis. United States,2015