Feasibility demonstration of a device for vitreous liquid biopsy incidental to intravitreal injection

Author:

Tumlinson Alexandre R.ORCID,Calara Jennifer M.,Azar Dimitri T.,Adamis Anthony P.,Vavvas Demetrios G.,Stewart Jay M.

Abstract

Purpose VitreoDx is an experimental device enabling push-button collection of a neat vitreous liquid biopsy incidental to an intravitreal injection. We explored the ability of the device to collect a sample usable for proteomic biomarker discovery and testing. Design Pilot study using ex vivo human eyes. Methods Non-vitrectomized, human eyes from nine donors 75–91 years of age were refrigerated in BSS and used within 5 days of death. Four VitreoDx devices fitted with 25G needles, and four staked needle insulin syringes with 30G needles, were inserted at equal intervals through the pars plana of each eye and held in place by a fixture. The sampling mode of each VitreoDx device was triggered to attempt to acquire a liquid biopsy up to 70 μL. The plunger of each insulin syringe was retracted to attempt to obtain a liquid biopsy with a maximum volume of 50 μL. Samples acquired with the VitreoDx were extracted to polypropylene cryovials, refrigerated to -80 ºC, and sent for offsite proteomic analysis by proximity extension assay with a focus on panels containing approved and pipelined drug targets for neovascular disease and inflammatory factors. Results Of the attempted liquid biopsies with the novel 25G VitreoDx, 92% (66 of 72) resulted in successful acquisition (>25 μL) while 89% (64 of 72) attempted by a traditional 30G needle resulted in a successful acquisition. Sample volume sufficient for proteomics array analysis was acquired by the VitreoDx for every eye. Detectable protein was found for 151 of 166 unique proteins assayed in at least 25% of eyes sampled by VitreoDx. Conclusions The high acquisition rate achieved by the prototype was similar to that achieved in previous clinical studies where a standard syringe was used with a 25G needle to biopsy vitreous fluid directly prior to standard intravitreal injection. Successful aspiration rates were likewise high for 30G needles. Together, these suggest that it is possible to routinely acquire liquid vitreous biopsies from patients who typically receive intravitreal injections with an injection device using a standard size needle without a vitreous cutter. Protein analysis shows that proteins of interest survive the sampling mechanism and may have potential to direct care in the future.

Funder

Twenty / Twenty Therapeutics, LLC

Publisher

Public Library of Science (PLoS)

Reference33 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3